Coating Thickness Gauge Leather Testing Equipment Measuring Range 0 - 1250 μm

iyi kalite Deri Test Cihazları satış için
iyi kalite Deri Test Cihazları satış için
Their service is professional and the quality of the products is very good.

—— Carlos from Brazil

Nice cooperation! We appreciated for your company's kind support on our projects. Very good service.

—— Rolland from South Africa

Evet makine aldık. Herşey yolunda. Herhangi bir sorunuz olursa size geri dönecektir.

—— Neringa

Ben sohbet şimdi

Coating Thickness Gauge Leather Testing Equipment Measuring Range 0 - 1250 μm

Çin Coating Thickness Gauge Leather Testing Equipment Measuring Range 0 - 1250 μm Tedarikçi
Coating Thickness Gauge Leather Testing Equipment Measuring Range 0 - 1250 μm Tedarikçi Coating Thickness Gauge Leather Testing Equipment Measuring Range 0 - 1250 μm Tedarikçi

Büyük resim :  Coating Thickness Gauge Leather Testing Equipment Measuring Range 0 - 1250 μm

Ürün ayrıntıları:

Place of Origin: China
Marka adı: Gaoxin
Sertifika: ISO 9001:2008
Model Number: GX-200

Ödeme & teslimat koşulları:

Minimum Order Quantity: 1 set
Fiyat: negotiation
Packaging Details: Special package
Delivery Time: 5010 working days
Payment Terms: T/T, FOB/CIF shenzhen
Supply Ability: 50 sets pert month
Contact Now
Detaylı ürün tanımı
Range: 0~1250 μm Error: 3%H+1μm(H is the measuring range)
Displaying accuracy: 0.1μm (0~100μm), 1μm (>100μm) Probe Type: Ferrous type, Non-ferrous type
Alarm: Configurable Alarm limit Dimensions: 155mm*68mm*27 mm
Weight: 230g

Coating Thickness Gauge

 

1. Product Name: Coating thickness gauge

 

2. Product Model: GX-200

 

3. Product Description:

 

The F type is designed based on the magnetic indicator induction principle, so it is for the Non-magnetic coatings of steel; The N type is designed based on the eddy current principle, so it is for the coating thickness of non-ferromagnetic metal like the anodic oxide coating of aluminum.

 

4. Product Features:

~Unique temperature compensation algorithm
~Support Multiple Calibration Mode
~Voice broadcast of result
~Wireless printing available

 

5.Technical Specification:

Range

0~1250 μm

Error

3%H+1μm(H is the measuring range)

Displaying accuracy

0.1μm (0~100μm), 1μm (>100μm)

Min. curvature Radius of the measured work

1.5mm(F Type),3mm(N Type)

Critical thickness of the base

0.5mm(F type),0.3mm(N type)

Min. diameter of the base

7mm(F type),5mm(N type)

Probe Type

Ferrous type, Non-ferrous type

Alarm

Configurable Alarm limit 

Working Voltage

3*1.5V AAA

Dimensions

155mm*68mm*27 mm

Weight

230g

 

6.Probes type

Probe model

F400

F1

F1/90

F10

N1

CN02

Operating Principle

 Magnetic Induction

 Eddy Current

 Measuring Range(μm)

 0-400

 0-1250

 0-10000

 0-1250
(Chromium Plating on Copper0-40μm)

 10-200

 Low Limit of Resolution(μm)

 0.1

 0.1

 10

 0.1

 1

 Indication Error

 One Point Calibration(μm)

 ±(3%H+1)

 ±(3%H+10)

 ±(3%H+1.5)

 ±(3%H+1)

 Two-point Calibration(μm)

 ±[(1~3)%H+0.7]

 ±[(1~3)%H+1]

 ±[(1~3)%H+10]

 ±[(1~3)%H+1.5]

 —

 Measuring Conditions

 Mini Radius of Curvature(mm)

 Convex 1

 Convex 1.5

 Straight

 10

 3

 Straight

 Diameter of Minimum Area(mm)

 Φ3

 Φ7

 Φ7

 Φ40

Φ5

Φ7 

 Mini Critical Thickness(mm)

0.2

0.5

0.5

2

0.3

 Unlimited

 